Specifications: - Residential Single Phase Unit

# 20 Year Design Life

# Surge Suppression – 2000 Joules

# Typical Protection For : Electrical Storms, Lightning Activity and Power Utility Spikes

# Let Through Voltage – 150V line-to-neutral

# Load Rating – 20A

# Six-Way Electrical Protection

# 220 Volt AC application

# Withstands surges to 480 VAC

# Self-healing metallized capacitors

# Low losses, 0.5 watt per kVAR 

# UL Recognized Pressure Sensitive Interrupter

# Interrupter for maximum 10,000 amp fault currents 

# Discharge system to reduce voltage to 50 volts or less within 1 minute of de-energization. Case rupture protection: Internal pressure sensitive devices incorporated to activate at end of life or misapplication.

# Operating temperature range of -40° C to +90° C 

# Flashpoint: + 182 degree C to + 200 degree C

# UL Listed

# Values +/- 2% of rating

# Hermetically sealed aluminum case with turn plate steel cover

# Phenolic insulating bushings

# Box size 6” x 6” x 4” 

# Operating Life: 60,000 hours with 95% survival

# General Enclosure: NEMA 3R Indoor/Outdoor

# Wire Rating: 600 Volts, THHN or MTW or THWN or AWM, Gasoline & Oil Resistant 11.